RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

Ask Latest Price
Video Channel
Brand Name :BIOVANTION
Place of Origin :China
MOQ :50kits
Assay Time :2 Hours
Assay Type :Immunological Assay
Detection Limit :Low
Expiration Date :18 months
Organism :Homo sapiens (Human)
Product Type :Research Test Kit
Reactivity :Highly reactive
Sample Type :Biological Samples
Sample Volume :50 µL
Specificity :High Specificity
Test Sample Type :Serum, Plasma
Test Species :Human
Time To Results :Rapid Results
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Research test for the quantitative determination of SAA Kit in human serum on automate chemistry analyzers

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

SAA (Serum Amyloid A) is is an acute-phase protein. During
inflammation, infectious and non-infectious diseases, its concentration in the blood can rise sharply within a few hours, and can rise to 1000 times the initial concentration. SAA is
related to HDL, and it can It regulates the metabolism of HDL
during inflammation. A particularly important feature of SAA is
that its degradation products can be deposited in different organs
in the form of amyloid A fibrils. This is a serious complication in
chronic inflammatory diseases; Elevated serum amyloid A is also
seen in atherosclerosis, diabetic nephropathy, acute myocardial
infarction, coronary heart disease, and chronic kidney disease

Components

Contents components Concentration

R1

PBS Buffer NaCl Surfactant

Antiseptic

0.1 mol/L Titer Titer

Titer

R2

Latex particles coated with SAA antibody

PB Buffer NaCl Surfactant

Antiseptic

>0.5mg/L

0.1 mol/L Titer Titer

Titer

Calibrator

/Control

SAA

Bovine serum albumin NaCl

Surfactant

Antiseptic

See Value Sheet Titer

Titer Titer

Titer

RUO Serum Amyloid A (SAA) Assay(Latex Immunoturbidimetric)

【Procedure】

Reagent preparation:

R1: Ready for use; R2: Ready for use. Wavelength:570nm Temperature:37℃

Direction: Increase

Blank Tube Calibration Tube Sample Tube
Sample 2ul
Calibrator 2ul
Deionized water 2ul
R1 200μl 200μl 200μl
Mix, incubate at 37℃ for 5 minutes.
R2 40μl 40μl 40μl

Mix, incubate at 37℃ for 5 minutes, zero setting for blank

tube, read the absorbance A calibrator and A sample

Calibration

It is recommended to use the SAA Calibrators for calibration. Dissolve the lyophilized SAA calibrator with 1ml distilled water, and dilute to 6 calibrators as follows,

Dilute 1 2 3 4 5 6
CAL (μl) 200 100 50 50 25 0

Normal

Saline (μl)

0 100 150 350 375 200
ratio 1 1/2 1/4 1/8 1/16 0

Calibration Method:Spline or other non-linear method

Quality control

It is recommended to use the SAA Quality Control level 1 and level 2 for daily quality control.

Two levels of controls should be assayed at least once a day. Values obtained should fall within a specified range.

Each laboratory should establish its own internal Quality Control scheme and procedures for corrective action if controls do not recover within the acceptable tolerances.

Calculation:

The analyzer automatically calculate the analyte concentration of each sample.