ISO13485 HIV Ab Ag Test Hiv 4th Generation Assay ELISA Kit 60 Minutes

Ask Latest Price
Video Channel
Brand Name :BIOVANTION
Model Number :96 Test/Kit
Certification :ISO13485
Place of Origin :CHINA
MOQ :1 Box
Payment Terms :L/C, Western Union, T/T
Supply Ability :50000 Box/Month
Delivery Time :5-8 working days
Price :Negotiable
Packaging Details :Carton
Specimen :Serum or Plasma
Read Time :60 Minutes
Storage :2-8℃
EXP :18 Months
Size :96 Test/Kit
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Hot Sale HIV Ab & Ag ELISA 96 Test/Kit
Catalog No.: BE701A

1. INTENDED USE

  • This is a 4th-generation assay for the simultaneous detection of antibodies to HIV-1 and HIV 2 as well as p24 antigen of HIV-1. The assay is based on recombinant and synthetic peptides for antibody detection and monoclonal antibody specific to the p24 protein of HIV-1.
  • It has great significance in the diagnosis of HIV infection / screen for donated blood to prevent transmission of HIV to recipients and as an aid in clinical diagnosis of HIV-related infections.


2. Materials provided with the kits:

ItemsDescription96T
1.Microplate96 wells
2.Negative Control1 mL ×1
3.Positive Control HIV-11 mL ×1
4.Positive Control HIV-21 mL ×1
5.Positive Control P24 Antigen1 mL ×1
6.Conjugate 13 mL ×1
7.Conjugate 212 mL ×1
8.Washing Buffer40 mL ×1
9.Substrate Solution A6 mL ×1
10.Substrate Solution B6 mL ×1
11.Stop Solution6 mL ×1
12.Plate Cover3 piececs
13.Insert1 copy


3. ASSAY PROCEDURE
1. Prepare Reagents: Dilute 1 volume of Washing Buffer with 19 volumes of distilled water, mix well.

2. Add Conjugate 1 and Samples: Open the foil pouch and remove the Microplate. Set up 1 well as Blank, 2
wells as Negative Control, 2 wells as Positive Control HIV-1, 2 wells Positive Control HIV-2 and 2 wells
Positive Control P24 Antigen. After dispensing 75μL of sample or Negative Control or Positive Control to
the respective wells, dispense 25μL of Conjugate 1 to each well (except the blank well). Gently vibrating
the plate.

3. Incubate: Cover the Microplate with plate cover and incubate the Microplate in a thermostat-controlled
water-bath or microplate incubator at 37℃ for 60 minutes.

4. Wash the Plate: Remove the plate cover. Aspirate the contents of all wells. Fill the wells with the diluted
washing buffer (10~20 seconds to soak) then aspirate again. Repeat the procedure for 5 times. Make sure
that the rest volume is minimal, by tapping plate onto absorbent paper.

5. Add Conjugate 2: Add 100μL of Conjugate 2 to each well (except the blank well).

6. Incubate: Cover the Microplate and incubate the plate at 37℃ for 30 minutes.

7. Wash the Plate: Repeat the wash procedure as in step 4.

8. Add Substrate: Add 50μL of Substrate Solution A and 50μL of Substrate Solution B to each well, mix well.
Cover and incubate at 37℃ for 30 minutes.

9. Stop reaction: Add 50μL Stop Solution to each well, mix well.

10. Read the absorbance at 450 nm. If a dual wavelength measurement is used, the reference wavelength should be selected from 620nm to 690nm.